PA-7500 running 11.1.x or higher reporting that actual power provided by the power supplies is less used power
138
Created On 06/26/26 08:57 AM - Last Modified 07/08/26 23:21 PM
Symptom
- On PA-7500 running on PANOS 11.1.x, the CLI output for the command “show chassis power” displays Actual power provide by the power supplies is less than the actual power used.
- As displayed in the output below, sum of actual power used by all the components (slots and the fan trays) = 6630W.
- However the sum of actual power provided by the Power Supply Units(PSx) = 6516W, which is less than the power used.
- No Operational impact because of the issue.
> show chassis power
Slot Component Card Status Power (w) Actual (w)
1 PA-7500-NPC-A Up 1150 439
2 PA-7500-NPC-A Up 1150 414
3 PA-7500-DPC-A Up 1200 739
4 PA-7500-DPC-A Up 1200 719
5 PA-7500-MPC-A Up 800 390
6 PA-7500-DPC-A Up 1200 763
7 PA-7500-DPC-A Up 1200 716
8 PA-7500-DPC-A Up 1200 741
9 PA-7500-DPC-A Up 1200 758
10 PA-7500-SFC-A Up 400 306
11 PA-7500-SFC-A Up 400 293
FANTRAY1 PA-7500-FAN-A Present 150 25
FANTRAY2 PA-7500-FAN-A Present 150 23
FANTRAY3 PA-7500-FAN-A Present 150 23
FANTRAY4 PA-7500-FAN-A Present 150 23
FANTRAY5 PA-7500-FAN-A Present 150 23
FANTRAY6 PA-7500-FAN-A Present 150 23
FANTRAY7 PA-7500-FAN-A Present 150 23
FANTRAY8 PA-7500-FAN-A Present 150 24
FANTRAY9 PA-7500-FAN-A Present 150 23
FANTRAY10 PA-7500-FAN-A Present 150 23
FANTRAY11 PA-7500-FAN-A Present 150 24
FANTRAY12 PA-7500-FAN-A Present 150 24
FANTRAY13 PA-7500-FAN-A Present 150 24
FANTRAY14 PA-7500-FAN-A Present 150 24
FANTRAY15 PA-7500-FAN-A Present 150 23
PS1 PAN-PWR-3600W-AC OK 3600 667 (+)
PS2 PAN-PWR-3600W-AC OK 3600 671 (+)
PS3 PAN-PWR-3600W-AC OK 3600 647 (+)
PS4 PAN-PWR-3600W-AC OK 3600 637 (+)
PS5 PAN-PWR-3600W-AC OK 3600 650 (+)
PS6 PAN-PWR-3600W-AC OK 3600 650 (+)
PS7 PAN-PWR-3600W-AC OK 3600 640 (+)
PS8 PAN-PWR-3600W-AC OK 3600 637 (+)
PS9 PAN-PWR-3600W-AC OK 3600 663 (+)
PS10 PAN-PWR-3600W-AC OK 3600 654 (+)
Provided: 36000 6516 <<
Used: 13350 6630 <<<
Remaining: 22650Environment
- PA-7500
- PANOS 11.1.x
Cause
- In older chassis models such as PA-7050/7080, the "Provided" power value was a static calculation based on PSU (Power Supply Unit) labels rather than actual real-time measurements. Because the firewall assumed these theoretical maximums were always available, it would attempt to power on new line cards even if the actual power supply was insufficient, leading to potential stability issues or failures.
- With PA-7500, Provided power is no longer a static theoretical number. It is a true, measured rolling average of the actual wattage the PSUs draw over a periodic polling interval. This allows the chassis to make informed decisions about whether it is actually safe to power on a new component based on the actual power currently available.
- Since an instantaneous snapshot of the Line Cards against a smoothed average from the PSUs is being compared, a brief traffic spike may cause the used value to momentarily look higher than the Provided average in the CLI output.
- The (+) symbol next to the PSUs Actual values (e.g., PS1: 667 (+)) visually warns the administrator about this averaging behavior.
Resolution
- Behavior is working as expected