Faltan interfaces LFC después del reinicio manual de la ranura en PA-7000
2981
Created On 07/14/22 01:55 AM - Last Modified 01/03/25 14:43 PM
Symptom
- Tarjeta de reenvío de registros (LFC) insertada en la ranura 7 (en PA-7080) o en la ranura 8 (PA-7050)
- Administror restarts the LFC card using the command
request chassis restart slot s7/s8 - Now the expected LFC interfaces are not displayed (lfc1/9 and lfc1/10) in the show command.
admin@PA-7050(active)> show interface all lfc1/1 10000/full/up 58:49:3b:fb:2a:00 lfc1/2 10000/full/up 58:49:3b:fb:2a:00 lfc1/3 10000/full/up 58:49:3b:fb:2a:00 lfc1/4 10000/full/up 58:49:3b:fb:2a:00 lfc1/5 10000/full/down(autoneg) 58:49:3b:fb:2a:00 lfc1/6 10000/full/down(autoneg) 58:49:3b:fb:2a:00 lfc1/7 10000/full/down(autoneg) 58:49:3b:fb:2a:00 lfc1/8 10000/full/down(autoneg) 58:49:3b:fb:2a:00
Nota : Aunque LFC está instalado en la ranura 7 u 8, dado que esta es la primera tarjeta LFC, la ranura/puerto se indica como " lfc1/x ".
Environment
- cortafuegos serie PA-7000 (7050 o 7080)
- Sistema operativo PAN compatible
- Tarjeta de reenvío de registros (LFC) instalada
Cause
- Reiniciar el LFC durante el tiempo de ejecución del sistema provocará que la ranura se reinicie sin que se vuelva a aplicar su configuración .
- El LFC se reiniciará pero perderá su configuración.
Resolution
Para resolver el problema, realice una compilar forzada:
admin@PA-7050(active)> configure
admin@PA-7050(active)# commit force
admin@PA-7050(active)# exit