Interfaces are not coming up on PA-5450 after restart
2375
Created On 01/04/23 03:17 AM - Last Modified 08/15/25 03:20 AM
Symptom
- PA-5450 Chassis restart on a High Availability (HA) Setup.
- HA Passive device is coming up as "non-functional" instead of "Passive"
Environment
- Palo Alto PA-5450
- PAN-OS 10.1.x, 10.2.x
- High Availability (HA)
Cause
Software Issue.
Resolution
Resolution:
- The issue is fixed under PAN-196445 in PAN-OS 10.1.7 and 10.2.3.
- Upgrade to the above versions or later will fix the issue
One of the following workaround will resolve the issue
- Run the following command from CLI.
>request high-availability state functional
- Perform a "Commit"