Bridgecrew : Error while opening the Code Module on Prisma Cloud
7694
Created On 02/18/22 17:46 PM - Last Modified 04/05/22 04:15 AM
Symptom
- Unable to use Code security feature on Prisma Cloud
- When trying to access Code security tab "Unauthorized page" or "something went wrong error" is seen.
Environment
- Stacks: All
- Product: Prisma Cloud Code security / Bridgecrew
Cause
Customer firewall's blocking underlying call to Bridgecrew URL
Note: Ensure that customer still has a valid license on Prisma Cloud for Bridgecrew
Resolution
- Prior to opening "Code" tab on Prisma Console, collect a HAR Trace (See Additional Information on how to start a HAR trace)
- Keep the HAR Trace running until you see the Error page
- One should see a "403" within the HAR trace for any "bundle.js" calls reaching out to Bridgecrew domain (highlighted in red in the Screenshot below)
- Once you see a "403", right click the domain and open in new tab
- This new tab will notify you if the Org firewall is blocking the "Bridgecrew.cloud" domain
- If so, please whitelist this in the org firewall and try this again