PA-5450 Unerwartetes Hochverfügbarkeits-Failover aufgrund von path_monitor HB Fehlern
8848
Created On 01/20/23 00:16 AM - Last Modified 02/27/24 14:47 PM
Symptom
- Geräte mit großen Sitzungen können plötzlich einen internen Pfadüberwachungsfehler auslösen, der zu HA einem Failover führt.
- mp-monitor.log (weniger mp-log mp-monitor.log) zeigen, dass core1 (DP0) stark ausgelastet ist.Alle anderen DP Kerne sind normal.
CPU load (%) during last 60 seconds:
core 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
* 5 4 4 4 3 4 3 3 3 4 4 4 3 3 3
* 6 5 4 4 4 4 4 4 4 4 4 4 4 4 4
* 9 7 6 6 6 6 6 6 6 6 6 6 6 6 6
* 12 9 8 8 8 8 8 8 8 8 8 8 8 8 8
* 13 10 9 9 9 9 9 9 9 9 8 8 9 9 9
* 11 9 8 8 7 8 8 8 8 8 8 8 8 8 8
* 9 7 6 6 6 6 6 6 6 6 6 6 6 6 6
* 10 7 6 6 7 7 7 7 7 6 7 7 7 7 6
* 12 9 8 8 8 8 8 8 8 8 8 8 8 8 8
* 24 9 8 8 8 8 8 8 8 8 8 8 8 8 8
* 70 9 8 9 9 9 9 9 8 9 9 9 8 9 9
* 100 8 8 8 8 8 8 8 8 8 8 8 8 8 8
* 100 8 8 8 8 8 8 8 8 8 8 8 8 8 8
* 100 9 9 9 9 9 9 9 9 9 9 9 9 9 9
* 100 13 12 12 12 13 12 13 12 13 12 12 12 12 13
* 100 10 10 10 10 11 10 11 10 11 10 10 11 10 10
* 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10
* 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10
- Firewall Failover mit den folgenden Fehlern im Systemprotokoll (Protokollsystem anzeigen).Wenn ein Failover auftritt, wirkt es sich auf alle DPC NC und Karten aus.
HA Slot 4 down; failure
HA Slot 3 down; failure
HA Slot 2 down; failure
HA Slot 1 down; failure
Chassis Master Alarm: HA-event
slot3dp0-path_monitor HB failures seen, triggering HA DP down
internal packet path monitoring failure, rastarting slot 5
link-monitor-down
- Globale Zähler (Zähler global anzeigen) zeigen das fehlende Abfrageintervall an.Pakete fehlen zwischen Poll1 und Poll2
Poll 1
flow_path_monitor_rx_from_mp 980489 27 info flow mgmt Path monitor packet received from MP
flow_path_monitor_tx_to_mp 980419 27 info flow mgmt Path monitor packet sent to MP
flow_path_monitor_tx_to_fe 439752 9 info flow mgmt Path monitor packet sent to FE
flow_path_monitor_rx_from_fe 439682 9 info flow mgmt Path monitor packet received from FE
Poll 2:
flow_path_monitor_rx_from_mp 980559 33 info flow mgmt Path monitor packet received from MP + 70
flow_path_monitor_tx_to_mp 980479 33 info flow mgmt Path monitor packet sent to MP + 60
flow_path_monitor_tx_to_fe 439782 11 info flow mgmt Path monitor packet sent to FE + 30
flow_path_monitor_rx_from_fe 439702 11 info flow mgmt Path monitor packet received from FE + 20Environment
- Palo Alto 5400 Serie firewall
- PANOS 10.1.6 oder niedriger.
- PANOS 10.2.2 oder darunter.
Cause
Software-Problem
Resolution
- Das Problem wurde in PAN-OS 10.2.3, 10.1.7, 10.1.6-h4 unter PAN-192551