PA-7050 - LFC will not stay powered on
497
Created On 10/26/22 16:53 PM - Last Modified 11/13/25 00:24 AM
Symptom
>show chassis status slot s8 Slot
Component Card Status Config Status Disabled 8 PA-7000-LFC-A Failure None * <<----------------
Card Status: 'Failure' Detail: Power not OK <<------------------
Config Status: 'None' Detail: Card is not in a valid state to receive configuration
Environment
- PA-7K
Cause
- Power supply failure on the LFC card.
Resolution
- RMA of LFC card
Additional Information
>show chassis status slot s8
Slot Component Card Status Config Status Disabled 8 PA-7000-LFC-A Failure None * Card Status: 'Failure' Detail: Power not OK Config Status: 'None' Detail: Card is not in a valid state to receive configuration
>show chassis power
Slot Component Card Status Power (w) 1 PA-7000-100G-NPC Starting 430 2 PA-7000-100G-NPC Starting 430 3 empty 4 PA-7050-SMC-B Up 500 5 empty 6 empty 7 empty 8 PA-7000-LFC Failure FANTRAY1 PA-7050-FANTRAY-L-A Present 180 FANTRAY2 PA-7050-FANTRAY-R-A Present 1120 PS1 CAR2548FPBCXZ03A OK 2500 (+) PS2 CAR2548FPBCXZ03A OK 2500 (+) PS3 CAR2548FPBCXZ03A OK 2500 (+) PS4 CAR2548FPBCXZ03A OK 2500 (+) Provided: 10000 Used: 2660 Remaining: 7340