How to troubleshoot port failure on ION devices
8002
Created On 01/26/24 21:38 PM - Last Modified 01/31/24 01:24 AM
Objective
To troubleshoot port failures on ION devices before proceeding with the RMA.
Environment
- Prisma SD-WAN
- ION devices
Procedure
- Check the status of the port LEDs. When the Link is up, the port LED must be green.
- Check for loose or damaged data cables.
- If the problem is isolated to one port, then try swapping cables.
- Verify the speed/duplex setting on both sides of the link and modify the same if required. Make sure the speed/duplex setting on the UI and CLI are the same.
- Check Admin up/down configuration - make sure that the port is not set as "admin down:.
- Check router/service provider modem connection/interface status on directly connected device.
- Check for any alerts/alarms events in the UI.
- If the above does not help resolve the issue. Open a support case.
Additional Information
Commands to run on CLI for troubleshooting
- dump overview - Displays system output
- dump interface config <interface> - To check admin up/down status
- dump interface status <interface> - To check speed/duplex setting