La tarjeta DPC no aparece en un firewall PA-5450
4076
Created On 07/26/24 18:44 PM - Last Modified 01/03/25 13:33 PM
Symptom
- DPC informa una falla al usar el comando de CLI " show chasis estado slot sx " (cambie x por el número de ranura)
- La tarjeta NC correspondiente también se apaga debido a una falla del DPC.
admin@xxxx-xxx-fw5450a> show chassis status
Slot Component Card Status Config Status Disabled
..............
3 PA-5400-DPC-A Failure None
...............
admin@xxxx-xxx-fw5450a> show chassis status slot s3
............
3 PA-5400-DPC-A Failure None
Card Status: 'Failure'
Detail: Path montior failure - Max restarts attempted
..........
admin@bdcm-burn-fw50a> show chassis status slot s1
Slot Component Card Status Config Status Disabled
1 PA-5400-NC-A PowerOff None
Card Status: 'PowerOff'
Detail: Attempting to power down Slot 1 because the Logically Paired Slot 3 (PA-5400-DPC-A) went from Up state to Failure state.
...............
Environment
- Cortafuegos PA-5450
- Sistema operativo PAN compatible
- Tarjeta de plano de datos (DPC)
- Tarjeta de red (NC)
Cause
El equipo de soporte deberá investigar la causa.
Resolution
Abra un caso de soporte para una mayor investigación.