ファイアウォールの再起動後にファイアウォールのSNMP MIB OID が変わる/変更される
889
Created On 11/05/24 00:52 AM - Last Modified 01/21/26 22:39 PM
Symptom
ファイアウォールを再起動する前のSNMPウォーク:
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.3 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.4 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.5 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.6 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.7 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.8 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: FE100 Core
ENTITY-MIB::entPhysicalName.14 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.15 = STRING: Power Supply #2 (right)
ファイアウォールの再起動後のSNMPウォーク:
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.3 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.4 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.5 = STRING: Power Supply #2 (right)
ENTITY-MIB::entPhysicalName.6 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.7 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.8 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.14 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.15 = STRING: Temperature: FE100 CoreEnvironment
- NGFW
- パンOS
- SNMP の
Cause
この問題は設計によって発生します:
DB が空の場合はデータが入力され、 SNMPデーモンの起動時にMIBテーブルの順序が含まれます。これはデバイスごとに行われるため、 SNMP MIBテーブルの順序はデバイスデバイスに異なる場合があります。
Resolution
MB 順序の問題を修正するために、以下のコマンドが導入されました。
> debug snmpd clear_persistence entity
このコマンドは、 SNMP OIDデータベースをリセットし、snmpd を再起動します。
ファイアウォールを再起動した状態で、またはSNMP MIBテーブルの順序が間違っている状態でコマンドを実行してください。