L'OID MIB SNMP du pare-feu est différent/change après le redémarrage du pare-feu
895
Created On 11/05/24 00:52 AM - Last Modified 01/21/26 22:39 PM
Symptom
Parcours SNMP avant le redémarrage du pare-feu :
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.3 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.4 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.5 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.6 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.7 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.8 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: FE100 Core
ENTITY-MIB::entPhysicalName.14 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.15 = STRING: Power Supply #2 (right)
Parcours SNMP après le redémarrage du pare-feu :
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.3 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.4 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.5 = STRING: Power Supply #2 (right)
ENTITY-MIB::entPhysicalName.6 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.7 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.8 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.14 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.15 = STRING: Temperature: FE100 CoreEnvironment
- NGFW
- PAN-OS
- SNMP
Cause
Ce problème est dû à la conception :
La base de données sera renseignée si elle était vide et contiendra l'ordre de la table MIB au démarrage du démon SNMP . Cela se fait par périphérique, donc l'ordre de la table MIB SNMP peut être différent d' un appareil à appareil.
Resolution
La commande ci-dessous est introduite pour résoudre le problème de commande MB :
> debug snmpd clear_persistence entity
Cette commande réinitialisera la base de données SNMP OID et redémarrera snmpd.
Veuillez exécuter la commande sur le pare-feu qui a été redémarré ou qui a mal ordonné la table MIB SNMP .