Firewall SNMP MIB OID ordering changes after firewall reboot
669
Created On 11/05/24 00:52 AM - Last Modified 01/21/26 22:39 PM
Symptom
SNMP walk before firewall reboot:
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.3 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.4 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.5 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.6 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.7 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.8 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: FE100 Core
ENTITY-MIB::entPhysicalName.14 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.15 = STRING: Power Supply #2 (right)
SNMP walk after firewall reboot:
ENTITY-MIB::entPhysicalName.1 = STRING: PA-3220
ENTITY-MIB::entPhysicalName.2 = STRING: Temperature: Broadwell MP Core
ENTITY-MIB::entPhysicalName.3 = STRING: Fan Tray
ENTITY-MIB::entPhysicalName.4 = STRING: Power Supply #1 (left)
ENTITY-MIB::entPhysicalName.5 = STRING: Power Supply #2 (right)
ENTITY-MIB::entPhysicalName.6 = STRING: Fan #1 RPM
ENTITY-MIB::entPhysicalName.7 = STRING: Fan #2 RPM
ENTITY-MIB::entPhysicalName.8 = STRING: Fan #3 RPM
ENTITY-MIB::entPhysicalName.9 = STRING: Temperature @ Rear Left[U54]
ENTITY-MIB::entPhysicalName.10 = STRING: Temperature @ Front Left[U62]
ENTITY-MIB::entPhysicalName.11 = STRING: Temperature @ Rear Right[U121]
ENTITY-MIB::entPhysicalName.12 = STRING: Temperature @ Front Right[U101]
ENTITY-MIB::entPhysicalName.13 = STRING: Temperature: 73XX DP Core
ENTITY-MIB::entPhysicalName.14 = STRING: Temperature: Qumran Switch Core
ENTITY-MIB::entPhysicalName.15 = STRING: Temperature: FE100 CoreEnvironment
- Next Gen Firewalls
- PAN-OS 10.1.x
- SNMP
Cause
Software Design.
Resolution
- New command is introduced to fix the MB ordering issue.
- This command will reset the SNMP OID database and restart the snmpd.
- Run the command on firewall with is rebooted, or having mis-ordered SNMP MIB table.
> debug snmpd clear_persistence entity