SFP 收发器诊断信息显示,当接口启动并处于活动状态时,Rx 功率为 0.00 mW

SFP 收发器诊断信息显示,当接口启动并处于活动状态时,Rx 功率为 0.00 mW

7699
Created On 04/25/24 09:04 AM - Last Modified 08/14/24 01:49 AM


Symptom


  • 将 SFP 收发器插入接口并且接口启动并处于活动状态后, show transceiver <interface-name>Rx 功率 显示为 0.00 mW
    > show transceiver ethernet1/14
    
    --------------------------------------------------------------------------------
             Port   Temperature      Voltage      Current    Tx Power    Rx Power
    --------------------------------------------------------------------------------
     ethernet1/14       36.99 C       3.29 V      5.83 mA     0.63 mW     0.00 mW
  • 然后,在不执行任何操作的情况下更新 Rx Power
    > show transceiver ethernet1/14
    
    --------------------------------------------------------------------------------
             Port   Temperature      Voltage      Current    Tx Power    Rx Power
    --------------------------------------------------------------------------------
     ethernet1/14       37.94 C       3.28 V      6.23 mA     0.65 mW     0.62 mW


Environment


  • Palo Alto 硬件防火墙
  • 支持的 PAN-OS
  • SFP收发器模块


Cause


  • 默认诊断监视器间隔为 3,600 秒(即 1 小时)。
  • 当接口首次插入或发生链路断开/启动事件后,诊断监视器需要一个小时才能运行并显示电源。

 



Resolution


  1. 使用较短的延迟(小于 3600 秒)设置诊断数据
  2. 在以下示例中,诊断监视器间隔为 10 秒
> set transceiver-monitor-rate seconds 10
注意:此命令在重新启动后不会持久存在。
 