Why PA-7000 has the following error Insufficient Cooling

Why PA-7000 has the following error Insufficient Cooling

276
Created On 07/22/22 04:35 AM - Last Modified 11/15/25 00:23 AM


Symptom


  1. AutoCommit does not complete
  2. The LED status on the device is red for Alarms and amber for Temperature and HA.
  3. Output of log with errors seen below
admin@FW1> show chassis inventory
Slot Component Serial Number Ports Revision Power (w)
Chassis 010108010359 1.0
empty

1 PA-7000-100G-NPC-A 015601002483 28 1.3 430
2 PA-7000-DPC-A 016901000585 0 1.0 490
3 PA-7000-DPC-A 016901000556 0 1.0 490
4 PA-7050-SMC-B 018501000997 0 2.0 500          <--module require gen2 fantray
5 PA-7000-100G-NPC-A 015601002723 28 1.3 430	<--module require gen2 fantray
6 PA-7000-DPC-A 016901000599 0 1.0 490
7 PA-7000-DPC-A 016901000613 0 1.0 490
8 PA-7000-LFC-A 018301001209 10 1.2 240		    <--module require gen2 fantray

FANTRAY1 PA-7050-FANTRAY 011108000272 1.0 520           <-- gen1 fantray
FANTRAY2 PA-7050-FANTRAY-R-A 021908001099 1.0 1120      <-- gen2 fantray

PS1 CAR2548FPBCXZ03A FM72660 3 2500 (+)
PS2 CAR2548FPBCXZ03A FM72622 3 2500 (+)
PS3 CAR2548FPBCXZ03A FM72734 3 2500 (+)
PS4 CAR2548FPBCXZ03A FM72635 3 2500 (+)
 
Output from ehmon.logs 
s4fpp ehmon.log 2022-07-06 16:23:48 2022-07-06 16:23:48.655 -0700 Sensor Alarm [False]: Fabric-2 Core = 95.000
s4fpp ehmon.log 2022-07-06 16:30:48 2022-07-06 16:30:48.852 -0700 Sensor Alarm [True ]: Fabric-2 Core = 95.200
s4fpp ehmon.log 2022-07-06 16:36:48 2022-07-06 16:36:48.727 -0700 Sensor Alarm [False]: Fabric-2 Core = 95.000
 
Output from Chasd logs:
mp chasd.log 2022-07-06 16:58:27 2022-07-06 16:58:27.684 -0700 Setting fan tray 1 speed to 5293 (3000 to 5400) for 0.96 (Fabric-1 Core:93.0)
mp chasd.log 2022-07-06 16:58:27 2022-07-06 16:58:27.684 -0700 Setting fan tray 2 speed to 11157 (3800 to 11500) for 0.96 (Fabric-1 Core:93.0)
mp chasd.log 2022-07-06 17:10:25 2022-07-06 17:10:25.611 -0700 Setting fan tray 1 speed to 5400 (3000 to 5400) for 1.00 (Fabric-1 Core:95.2)
mp chasd.log 2022-07-06 17:10:25 2022-07-06 17:10:25.612 -0700 Setting fan tray 2 speed to 11500 (3800 to 11500) for 1.00 (Fabric-1 Core:95.2)
mp chasd.log 2022-07-06 17:10:25 2022-07-06 17:10:25.612 -0700 Chassis Master Alarm: Temperature
 
admin@FW1> show chassis status
Slot Component Card Status Config Status Disabled
1 PA-7000-100G-NPC-A InsufficientCooling None
2 PA-7000-DPC-A InsufficientCooling None
3 PA-7000-DPC-A InsufficientCooling None
4 PA-7050-SMC-B Up None
5 PA-7000-100G-NPC-A InsufficientCooling None
6 PA-7000-DPC-A InsufficientCooling None
7 PA-7000-DPC-A InsufficientCooling None
8 PA-7000-LFC-A InsufficientCooling None *




 


Environment


  • All PAN-OS
  • Affect PA-7000 Series


Cause


The cause is due to the mixing of gen1 and gen2 fantray which are incompatible to each other.

Resolution


Replace gen1 fantray with gen2 fantray

Actions
  • Print
  • Copy Link

    https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA14u000000CqiZCAS&lang=en_US&refURL=http%3A%2F%2Fknowledgebase.paloaltonetworks.com%2FKCSArticleDetail