Panorama commit error: Device xxxxxxxxxx variable table has undefined values, please use get value from device or define it first

Panorama commit error: Device xxxxxxxxxx variable table has undefined values, please use get value from device or define it first

24208
Created On 03/16/21 15:52 PM - Last Modified 12/07/22 21:35 PM


Symptom


  • Unable to Push the commit to the Firewall. You are seeing commit failures due to undefined variable values:
Details: . Device 007051000049130 variable table has undefined values, please use get value from device or define it first


 


Environment


  • Panorama


Cause


This issue occurs when you have a variable in "Panorama > Templates > Template variables > Manage" that is not assigned a value.

Resolution


Check if the variable is being used anywhere by searching in the "Search" bar in the top right of the Webgui and then remove the variable or assign a value to the variable.