What is the SNMP OID for PA-7050 Power supplies?

What is the SNMP OID for PA-7050 Power supplies?

8952
Created On 04/20/20 16:00 PM - Last Modified 12/18/20 00:50 AM


Question


What is the SNMP OID for PA-7050 Power supplies?

Environment


  • Palo Alto PA-7050 Firewalls.
  • PAN-OS 8.1.0 and above.
  • SNMP Configured.


Answer


The OID 1.3.6.1.2.1.131.1.1.1.5.28    gives Alarm status for Power Supply1.
The OID 1.3.6.1.2.1.47.1.1.1.1.7.28   gives supply information of Power Supply1.

Replace the last digits with 29 for Power Supply2, 30 for Power Supply3, and 31 for Power Supply4.

Example: CLI output of power supply on  PA-7050
> show system environmentals power-supply

----Power Supplies----
Slot     Description    Alarm  Inserted
S4     Power Supply #1  True   True
S4     Power Supply #2  False  True
S4     Power Supply #3  False  True
S4     Power Supply #4  False  True

Snmpget for power supply1 results in 
 .1.3.6.1.2.1.131.1.1.1.5.28   Name/OID: entStateAlarm.28; Value (OctetString): major
 .1.3.6.1.2.1.47.1.1.1.1.7.28  Name/OID: entPhysicalName.28; Value (OctetString): Power Supply #1

Note: entStateAlarm, the value is major if Alarm is true, no value if Alarm is false. In the above example, it is true for power supply 1.