How to Determine and Replace Failed Raid Drives in M-100

How to Determine and Replace Failed Raid Drives in M-100

55180
Created On 09/26/18 13:47 PM - Last Modified 08/11/20 14:37 PM


Symptom


Once support has determined a failed HDD you can follow steps below to replace the failed drive. 



Environment


  • Panorama M-100
  • PAN-OS 7.1 and above.


Resolution


To swap the RMA'd hard drives, perform the following steps:
  1. Identify the failed drive.
       ( Example below the output shows that disk drive A2 failed and the drive model is ST91000640NS.)
admin@M-100> show system raid detail
Disk Pair A                                     Available
  Status                                      clean, degraded
  Disk id A1                                     Present
      model        : ST91000640NS
      size         : 953869 MB
      status       : active sync
  Disk id A2                                      Present
      model        : ST91000640NS
      size         : 953869 MB
      status       : failed
 
  1. Remove the failed hard disk drive (HDD) pair from the RAID 1 array. 
admin@M-100> request system raid remove A2    (A2 is chosen based on the example above)
 
  1. Remove the failed HDD and insert replacement. (Verify it is the same model is current one listed in raid detail output)
 Remove and install M-100 HDD
  1. Once installed, Add the replacement drive to the RAID 1 array.
admin@M-100> request system raid add A2
        (The system automatically configures the new drive to mirror the contents of the other drive in that RAID 1 array.)
 
  1. Continue to view RAID status until you see that the disk pair (Disk Pair A in this example) shows Available and both drives show the status active sync. To view RAID status, run the following command: show system raid detail
      (Example of RAID 1 still building )
> show system raid detail
Disk Pair A                                                            Available 
Status                        clean,degraded, recovering (14% complete)
Disk id A1                                                             Present 
  model                     : ST91000640NS
  size                      : 953869 MB 
  status                    : active sync 
Disk id A2                                                             Present 
  model                     : ST91000640NS
  size                      : 953869 MB 
  status                    : spare rebuilding
         
           
(Example of RAID 1 building complete )
admin@M-100> show system raid detail
Disk Pair A                                                         Available
Status                           clean
Disk id A1                                                          Present
  model                        : ST91000640NS
  size                         : 953869 MB
  status                       : active sync
Disk id A2                                                          Present
  model                        : ST91000640NS
  size                         : 953869 MB
  status                       : active sync
      Note: Depending on the size of the disk, it may take 2 to 3 hours for the disks to come in RAID. Once completed, reboot the Panorama M-100, so that system initializes with a new pair of hard disks.
 

 



Additional Information


  • For information on how to recover logs after swapping RAID disks in a log collector M-100, refer to: M-100 RMA Process
  • RAID Disk pairs need to be identical make and model so they are shipped in pairs. Replacement of both Disks is suggested to avoid mismatch of disk pair causing RAID to fail. For steps on replacing both drives to match see M-100 Appliance Hardware Reference Guide