Ci-dessous est un exemple de sortie pour afficher les seuils thermiques maximum et minimum, affichant max = 60 c et min = 5 c.
Utilisez la commande CLI suivante:
> afficher le filtre d'état du système env. * | match thermique
env. S1. thermal. 0: {'alarm': false, 'avg': 30,800, 'desc': temperature @ 10g physique [U171], 'hyst': 2,750, 'max': 60,000, 'min': 5,000, 'samples': [30,500,
30,500, 31,000, 31,000, 31,000,],}
env. S1. thermal. 1: {'alarm': false, 'avg': 41,500, 'desc': temperature @ Jaguar [U172], 'hyst': 2,750, 'max': 60,000, 'min': 5,000, 'samples': [41,500,
41,500, 41,500, 41,500, 41,500,],}
env. S1. thermal. 2: {'alarm': false, 'avg': 36,000, 'desc': temperature @ Tiger [U173], 'hyst': 2,750, 'max': 60,000, 'min': 5,000, 'samples': [36,000,
36,000, 36,000, 36,000, 36,000,],}
env. S1. thermal. 3: {'alarm': false, 'avg': 34,200, 'desc': temperature @ dune [U174], 'hyst': 2,750, 'max': 60,000, 'min': 5,000, 'samples': [34,000,
34,000, 34,000, 34,500, 34,500,],}
Remarque: une alarme se déclenchera si la température atteint au-delà de 60 C. La température maximale de l'alarme diffère entre les plates-formes de Palo Alto Networks.