Unable to Configure RAID with Different SSD Drive Models on PA-5000 Series Firewalls

Unable to Configure RAID with Different SSD Drive Models on PA-5000 Series Firewalls

18243
Created On 09/25/18 17:51 PM - Last Modified 09/05/24 20:21 PM


Symptom


  • A PA-5000 Series firewall needs to be configured for RAID 1
  • The device has mismatched SSD drive models
  • When the second drive is inserted into the drive bay and the device is powered on, it does not boot into the maintenance mode.
  • The RAID details on the device do not show the second drive mirroring or sync status, as shown below:
> show system raid detail

Overall RAID status                        Good

----------------------------------------------------------------------
Drive status

  Disk id 1                            Present    (DENCSTE251M21-01)

  Disk id 2                            Present    (WDC WD1600BEKT-0)

--------------------------------------------------------------------

Partition status

panlogs                        clean, degraded

  Drive id 1                      active sync

maint                          clean, degraded

  Drive id 1                      active sync

sysroot0                      clean, degraded

  Drive id 1                      active sync

sysroot1                      clean, degraded

  Drive id 1                      active sync

pancfg                        clean, degraded

  Drive id 1                      active sync

panrepo                        clean, degraded

  Drive id 1                      active sync

swap                          clean, degraded

  Drive id 1                      active sync

 


Environment


  • PA-5000 Series
  • Configure RAID with Different SSD Drive Models


Cause


The Palo Alto Networks PA-5000 Series platform must have identical SSD drive models for RAID 1 configuration. An example of the RAID details on a properly configured device is shown below:
 

> show system raid detail

Overall RAID status                        Good

----------------------------------------------------------------------

Drive status

  Disk id 1                            Present    (WDC WD1600BEKT-0)

  Disk id 2                            Present    (WDC WD1600BEKT-0)

-----------------------------------------------------------------------

Partition status

panlogs                                  clean

  Drive id 1                      active sync

  Drive id 2                      active sync

maint                                    clean

  Drive id 1                      active sync

  Drive id 2                      active sync

sysroot0                                clean

  Drive id 1                      active sync

  Drive id 2                      active sync

sysroot1                                clean

  Drive id 1                      active sync

  Drive id 2                      active sync

pancfg                                  clean

  Drive id 1                      active sync

  Drive id 2                      active sync

panrepo                                  clean

  Drive id 1                      active sync

  Drive id 2                      active sync

swap                                    clean

  Drive id 1                      active sync

  Drive id 2                      active sync

 



Resolution


Use identical SSD Drive

 



Additional Information


For PA-5200 Series See Replace a Drive on a PA-5200 Series Firewall

Actions
  • Print
  • Copy Link

    https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClKXCA0&refURL=http%3A%2F%2Fknowledgebase.paloaltonetworks.com%2FKCSArticleDetail