How to Check for CRC Errors on an Interface

How to Check for CRC Errors on an Interface

71960
Created On 09/25/18 17:46 PM - Last Modified 06/13/23 04:54 AM


Resolution


Details

To check for CRC errors across the interfaces on a Palo Alto Networks device, run the following CLI command:

> show system state filter sys.s1.* | match crc

 

If there are any CRC errors on an interface, the "bad_crc" counter will appear in the output. The following sample output shows that the s1.p6 (ethernet1/6) interface experienced bad_crc:

sys.s1.p6.detail: {'bad crc': 0x6c1, ...

CRC-errors-53293.png

 

If the command does not return an output, none of the interfaces experienced bad_crc errors.

 

owner: mvenkatesan



Actions
  • Print
  • Copy Link

    https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClJVCA0&refURL=http%3A%2F%2Fknowledgebase.paloaltonetworks.com%2FKCSArticleDetail